Friedrich PDE12K3SF 12,000 BTU Packaged Terminal Air Conditioner with 3.0 kW Electric Heat, R-410A Refrigerant, 10.7 Energy Efficiency Ratio and 3 Cool/Heat Fan Speeds
Product Description
Friedrich has always been known for making the worlds finest air conditioners. All New For 2012 is the Friedrich "SF" Series PTAC. The new SF Series has been completely re-engineered and re-designed for improved efficency. Now with a new two motor design and tengential blower wheel resulting in a more uniform
airflow over a wider path for faster,more even air distribution throughout the room and improved sound levels
Friedrich is also the only PTAC with 3 fan speeds in cooling and heating mode. Soft start/stop fan delay feature reduces transitional noise that is usually
associated with compressor start-up. The new SF line has improved energy efficiency ratings (EER) for increased energy savings. Also new for 2011 is a universal heater in all models. Now you can change the heater size in any unit simply by changing the power cord. No more need to swap units from room to room or waiting for an exchange from the factory. Want to know more about the Friedrich SF Series PTAC? Contact your RoomAire.com rep today by calling 1-800-891-4729.
Features
New, quieter PTAC design with improved air distribution
New Two Motor Design
With separate indoor and outdoor motors, the indoor motor can run at slower speeds which reduces sound levels indoors.
New Tangential Blower Wheel
Tangential blower wheel has nearly 5x the surface area of a typical fan used on other pTAcS. The result is more uniform airflow over a wider path for faster, more even air distribution throughout the room and improved sound levels.
Air is blown over the entire length of the tangential wheel into the room in a uniform laminar airflow.
3 Speed Fan
Friedrich is the only major PTAC brand with 3 fan speeds in cooling and heating mode.
Soft start/stop fan delay feature reduces transitional noise that is usually associated with compressor start-up.
Universal Heater/Power Cord
All PTAC units ship complete with the standard power cord for that model (7K, 9K and 12K = 3.0 kW and 15K = 5.0 kW). If you want to adjust the heater size on any PTAC unit simply unplug the attached power cord and connect the desired size. It is important to ensure that all wiring and building connections are sized properly for the power cord as well.
Universal heater allows installers to change the heat output of the pTAc by changing the power cord, simplifying ordering and installation.
Comfort & Productivity
° Intuitive unit controls are easy to operate
° Constant room comfort monitoring
° "Instant Heat" heat pump mode quickly heats a room to the desired temperature for increased comfort
° Even heat monitoring checks room temperature and automatically adds heat boost if necessary
° The digital control panel will automatically run the fan to briefly sample the room temperature every nine minutes to ensure desired conditions are maintained
Durability
° Durable front panel with break proof control door and design
° Room freeze protection - heat initiated if temperature falls to 40°F in an unoccupied room, raising temperature to 46°F
° Random compressor restart protects electrical systems from overload when power is restored
° Tamper-resistant grille
° Durable, powder coat paint finish
° Indoor coil frost sensor protects the compressor to lengthen the life of the unit
° Diamonblue technology anti-corrosion protection treatment provides added endurance and protection in coastal or corrosive environments
Sound Reduction Technology
° Two permanently lubricated fan motors for added durability and quiet operation
° Quiet, efficient rotary compressor mounted with vibration isolators to keep the compressor running smoothly and quietly.
Maintenance & Installation Features
° Universal heaters with heat capacities determined by the power cord used with the unit.
° Service error code memory storage facilitates improved unit diagnostics.
° Emergency heat override ensures heat mode operation even in the unlikely event of compressor failure
° Maintenance friendly design with easy access to components for cleaning and repairs including liftout air filters
° Operating range 0° - 115° F. (Field-supplied modifications to extend operating range.)
Energy Usage & Management
° EERs up to 12.0; COPs up to 3.4 for increased energy savings
° Owners and operators have the flexibility to set separate heat and cool range limits
° Desk control ready allowing hotel owners to control units from a central location
° Electronic defrost control ensures more run time in the efficient heat pump mode
Health & IAQ
° Fresh air damper control to bring in fresh outside air when desired
° Washable, antimicrobial air filters
New Two Motor Design
With separate indoor and outdoor motors, the indoor motor can run at slower speeds which reduces sound levels indoors.
New Tangential Blower Wheel
Tangential blower wheel has nearly 5x the surface area of a typical fan used on other pTAcS. The result is more uniform airflow over a wider path for faster, more even air distribution throughout the room and improved sound levels.
Air is blown over the entire length of the tangential wheel into the room in a uniform laminar airflow.
3 Speed Fan
Friedrich is the only major PTAC brand with 3 fan speeds in cooling and heating mode.
Soft start/stop fan delay feature reduces transitional noise that is usually associated with compressor start-up.
Universal Heater/Power Cord
All PTAC units ship complete with the standard power cord for that model (7K, 9K and 12K = 3.0 kW and 15K = 5.0 kW). If you want to adjust the heater size on any PTAC unit simply unplug the attached power cord and connect the desired size. It is important to ensure that all wiring and building connections are sized properly for the power cord as well.
Universal heater allows installers to change the heat output of the pTAc by changing the power cord, simplifying ordering and installation.
Comfort & Productivity
° Intuitive unit controls are easy to operate
° Constant room comfort monitoring
° "Instant Heat" heat pump mode quickly heats a room to the desired temperature for increased comfort
° Even heat monitoring checks room temperature and automatically adds heat boost if necessary
° The digital control panel will automatically run the fan to briefly sample the room temperature every nine minutes to ensure desired conditions are maintained
Durability
° Durable front panel with break proof control door and design
° Room freeze protection - heat initiated if temperature falls to 40°F in an unoccupied room, raising temperature to 46°F
° Random compressor restart protects electrical systems from overload when power is restored
° Tamper-resistant grille
° Durable, powder coat paint finish
° Indoor coil frost sensor protects the compressor to lengthen the life of the unit
° Diamonblue technology anti-corrosion protection treatment provides added endurance and protection in coastal or corrosive environments
Sound Reduction Technology
° Two permanently lubricated fan motors for added durability and quiet operation
° Quiet, efficient rotary compressor mounted with vibration isolators to keep the compressor running smoothly and quietly.
Maintenance & Installation Features
° Universal heaters with heat capacities determined by the power cord used with the unit.
° Service error code memory storage facilitates improved unit diagnostics.
° Emergency heat override ensures heat mode operation even in the unlikely event of compressor failure
° Maintenance friendly design with easy access to components for cleaning and repairs including liftout air filters
° Operating range 0° - 115° F. (Field-supplied modifications to extend operating range.)
Energy Usage & Management
° EERs up to 12.0; COPs up to 3.4 for increased energy savings
° Owners and operators have the flexibility to set separate heat and cool range limits
° Desk control ready allowing hotel owners to control units from a central location
° Electronic defrost control ensures more run time in the efficient heat pump mode
Health & IAQ
° Fresh air damper control to bring in fresh outside air when desired
° Washable, antimicrobial air filters
Quick Specs:
Dimensions & Weights | |
Sleeve Width: | 42" |
Front Cover Width: | 42" |
Sleeve Depth: | 13 3/4" |
Front Cover Depth: | 7 3/4" |
Sleeve Height: | 16" |
Front Cover Height: | 16" |
Cutout Width: | 42 1/4" |
Cutout Height: | 16 1/4" |
Package Width: | 43 1/2" |
Package Depth: | 23" |
Package Height: | 19 3/4" |
Net Weight: | 116 lbs. |
Shipping Weight: | 136 lbs. |
Performance Data | |
Cooling: | 12,000/11,800 BTU/Hr. |
Power: | 1,120/1,120 Watts |
EER: | 10.7/10.5 |
Dehumidification: | 2.7 Pints/Hr. |
Sensible Heat Ratio: | 0.67 |
R-410A Charge: | 35.27 Oz. |
Electrical Data | |
Voltage (1 Phase, 60 Hz): | 230/208 Volts |
Volt Range: | 253-187 |
Current: | 5.1/5.3 Amps |
Power Factor: | 0.99 |
Compressor LRA: | 27.0 Amps |
Compressor RLA: | 5.0 Amps |
Fan Motor: | 0.031 HP |
Airflow Data | |
Indoor CFM - High: | 360/350 |
Indoor CFM - Medium: | 330/310 |
Indoor CFM - Low: | 310/280 |
Vent CFM: | 75 |
Electric Heating | |
Heater Watts: | 3,000/2,450 Watts |
Voltage: | 230/208 Volts |
Heating: | 10,236/8,360 BTU/Hr. |
Heating Current: | 13.2/12.2 Amps |
Min. Circuit Ampacity: | 16.8/15.6 |
Branch Circuit Fuse: | 20 Amps |